Release time:
2024-09-05
1. The setting of the travel limit switch, the power of the door is selected by default
The setting process for the first level of programming, through the opening and closing of the door stroke limit measurement, can be achieved in the process of opening and closing the door torque detection and force of the default selection.
2. The steps are as follows:
(1) After the power is on, it is in the waiter state. At this time, the motherboard status indicator is always on. If the motherboard status indicator is not on, please check whether the power is on.
(2) setting of garage door travel limit
Press and hold the function key of the electric control box for 3 seconds until the state indicator light flashes slowly (the operation indicator light goes out), release the function key, then adjust the door body to a reasonable position through the "" key and "-" key (press the "" key to open the door, press the "-" key to close the door), press the function key on the electric control box to confirm and save. At this time, the state indicator light flashes out and automatically turns to slow flash, (This leads to the next procedure-door closing travel limit setting).
(3) When the door closing travel limit switch sets the running light to flash slowly (the status light is off), press the "reduce" key to move the door down to the appropriate position (you can press the "" key and the "-" key to make fine adjustments). Press the function key to confirm the save, and the running light will flash several times and then go out.
(4) After the automatic detection of the electric control box and the default opening and closing power closing stroke setting program, the door body can automatically open and close the door, thus completing the steps of detection and default power, and then the status light is always on. The above settings that is completed the basic debugging, you can use the garage door.
3. Manual setting of opening and closing force
This process for the two level programming, generally do not have to debug. In order to meet the different users of the motor to open the door resistance stop, close the door resistance rebound function sensitivity and reliability of the different requirements set.
(1) Strength analysis description
The manually set opening and closing force refers to the force increased on the basis of the opening and closing force automatically detected by the motor. Each is divided into 4 gears, and the first gear Z is small. The motor automatically defaults to the first gear for closing the door and the second gear for opening the door.
(2) Setting process:
Press the "P" key for about 6 seconds. When the red light and green light are always on at the same time, set the door opening force first, press the "" key to increase and press the "-" key to decrease. The green light shows that the number of slow flashes is the gear of the current force. After selected, press "P" key to confirm and save. Automatically enter the closing force setting, (red and green lights are also on at the same time) press the "" key to increase the "-" key to decrease, the red light shows that the number of slow flashes is the current value, press the "P" key to confirm, save and exit the program. The red light becomes constant.
4, garage door manual remote control code and code elimination
(1) Garage door code elimination
Press and hold the code key for about three seconds until the indicator light goes out, then the code elimination step is completed.
(2) Garage door pair code
Press and hold the code alignment key of the remote control, and the code alignment indicator light will always be on, then press the required code alignment key (A or B) on the manual wireless remote control 2 times, and the code alignment indicator light of the remote control will change from constant on to flashing.
Key words: Qingdao fast door; Qingdao industrial lifting door