Function Debugging and Testing Method of Fast Induction Door
Release time:
2023-10-31
In recent years, with the improvement of the level of science and technology, the functions of the fast sensor door are constantly improving. At the same time, debugging and testing of the major functions of the fast door must also attract everyone's attention. When testing the function of high-speed rolling doors, which aspects should be taken and what are the specific testing and debugging methods?
Generally speaking, the function debugging and testing of the fast sensor door is generally carried out from the following aspects. The specific detection methods are as follows:
1. Emergency stop button function test
The function of the emergency stop button is specially designed when the fast induction door body is running in an emergency situation. It has a positive effect on the protection of personal safety. When testing the function of the quick door emergency stop button, you can press this emergency stop button during the operation of the door body to see if the quick door body stops immediately. If the door does not stop immediately, you need to check the reason, to see if the emergency stop button failure or damage, damage and to repair.
2. Infrared anti-smashing performance debugging
Infrared anti-smashing function is also a safety protection device for fast induction doors. During the detection, the infrared shooting system can be cut off during the falling process of the Shenzhen high-speed door body to see if the fast rolling door body rebounds to the opening position in time. Note: When testing the infrared anti-smashing function, be sure to pay attention to your own safety to prevent accidents caused by infrared system failure.
3. Automatic opening function detection
Automatic opening is one of the reasons why fast induction doors are loved by industrial enterprise users, and it is also one of the most important functions of high-speed rolling doors. To detect this function, vehicles and personnel can be used to simulate the actual situation to observe whether the door can be opened in time and whether there is no dead angle signal coverage at all angles.
4. Up and down limit debugging test
The upper and lower limit positions are related to the daily use of the high-speed door. Once the position is not accurate, the sealing and energy-saving function of the fast door cannot be guaranteed. When the upper and lower limit test is carried out, the door body can be operated upward by pressing the up button in the stationary state of the door body. After buffering and completely stopping, it is judged whether the lifting height meets the requirements of the user. If the requirements are not met, debug again. According to the same method, press the down button, and after the door body falls completely, check whether the stop position at the end of the PVC fast door body is in place, and adjust it in time if it is not in place.